TECHNICAL
NOTES |
| |
| FLANGED SYSTEM OPERATING PRESSURES |
| |
- Maximum pressure for any flanged system
is 150 psi. At elevated temperatures the pressure capability
of a flanged system must be derated per the following
chart, subject to the following:
- PVC and CPVC flanges in sizes 2.5" to
3-inch and 4-inch threaded must be back welded
for the above pressure capability to be applicable.
- Threaded Polypro flanges in sizes
1/2" through 4", as well as the 6" back
weld socket flange, are not recommended for pressure
applications (drainage only).
|
| |
| MAXIMUM
OPERATING PRESSURE (PSI) |
|
Operating
Temperature (°F)
|
FACTORS
|
|
PVC
|
CPVC
|
PP
|
PVDF
|
|
|
1.00
|
1.00
|
1.00
|
1.00
|
|
|
0.90
|
0.96
|
0.97
|
0.95
|
|
|
0.75
|
0.92
|
0.91
|
0.87
|
|
|
0.62
|
0.85
|
0.85
|
0.80
|
|
|
0.50
|
0.77
|
0.80
|
0.75
|
|
|
0.45
|
0.74
|
0.77
|
0.71
|
|
|
0.40
|
0.70
|
0.75
|
0.68
|
|
|
0.35
|
0.66
|
0.71
|
0.66
|
|
|
0.30
|
0.62
|
0.68
|
0.62
|
|
|
0.22
|
0.55
|
0.65
|
0.58
|
|
|
N.R.
|
0.47
|
0.57
|
0.52
|
|
|
N.R.
|
0.40
|
0.50
|
0.49
|
|
|
N.R.
|
0.32
|
0.26
|
0.45
|
|
|
N.R.
|
0.25
|
*
|
0.42
|
|
|
N.R.
|
0.18
|
N.R.
|
0.36
|
|
|
N.R.
|
0.15
|
N.R.
|
0.33
|
|
|
N.R.
|
N.R.
|
N.R.
|
0.25
|
|
|
N.R.
|
N.R.
|
N.R.
|
0.18
|
|
| N.R.
= Not Recommended |