Data shown is calculated from WIlliams
and Hazen formula: H=(3.023/C1.852)(V1.852/D1.167) using
C-150. For water at 60°F. Where H = head loss, V
= fluid velocity ft./sec., D = diameter of pipe, ft.
C = coefficient representing roughness of pipe interiour
surface.
Fittings Table: all measurements are
in equivalent feet of pipe.
Piping Table: velocity measured in feet/second,
friction loss measured in feet of water head per 100
feet of pipe.